Gold Film Fence-line Hydrogen Sulfide Monitoring System
The Jerome? 651 monitoring system from Arizona Instrument LLC is the system you need to solve your hydrogen sulfide monitoring problems. Designed to provide long-term monitoring even in extreme weather conditions, it can be stationed at any location. Multiple units can be linked to form a perimeter monitoring system. Data logging and radio telemetry capabilities make downloading data convenient and easy from a remote PC.
Unattended:
The 651 is designed for set-and-forget hydrogen sulfide monitoring, inside or out.
Flexible:
A detachable hand-held hydrogen sulfide analyzer is contained within the unit for pinpointing a gas source.
Smart Alarms:
Define alarm points that meet your needs and receive email notifications and warnings.
Wireless:
Measurement data is transmitted wirelessly from 651 stations to the user’s PC.
Rugged:
The 651 is housed in a Nema-rated box, insulated, air conditioned and ready for nearly any environment.
Specifications
Detection Range | 3 ppb (0.003 ppm) to 50 ppm |
Resolution | 0.001, 0.01, 0.1, and 1 ppm |
Accuracy | ±0.005 ppm at 0.05 ppm ±0.05 ppm at 0.5 ppm ±0.5 ppm at 5 ppm ±2 ppm at 25 ppm |
Sample Intervals | 1, 2, 5, 10, 15, 30, 60 or 120 minutes |
Regeneration Intervals | 6, 12, 24 and 48 hours |
Flow Rate | 150 mL/min |
Operating Environment | -40 to +55°C, non-explosive, 0-100% relative humidity |
Result Units | ppm, ppb |
Data Storage Capacity | 50,000 readings |
Power Requirements (651 Unit) | 100-120 VAC, 50/60 Hz, 7 A or 210-240 VAC, 50/60 Hz, 4 A |
Control Board Fuse | Fast-acting IEC 1.6 A 250 V, 5 mm x 20 mm |
Case Construction | Polyester with insulation to reduce heat transfer |
Battery (Detatched 631-X Unit) | Rechargeable NiCad 6 hour life |
Estimated Sensor Life | 3 to 6 months depending on operating conditions |
Display | 8 digit alphanumeric LCD |
Output | Nano Radio |
Analog | 4-20 mA passive current loop |
Dimensions | 26″ W x 25″ H x 9″ D (67 cm W x 64 cm H x 23 cm D) |
Weight | 52 lbs. (24 kg) |
Warranty | 1 year, factory parts and labor except for 631-X sensor |
Nano Radio Modem Specifications
Frequency | 2.4 – 2.4835 GHz (2400 MHz) 49 selectable channels |
Serial Interface | RS-232 |
Power Requirements | 10-30 VDC, 450 mA |
Operating Temperature | -40°C to 75°C |
Range | Up to 4 miles (6.4 km) “l(fā)ine of sight.” Longer distances may be obtainable through use of a high gain antenna or by using the optional Radio Repeater |
Features-
Perimeter Monitoring: Multiple Jerome? 651 units can be linked to form a perimeter monitoring system to help locate the source of H2S and ensure safety and compliance.
Detachable Unit: Quickly and easily sweep an area for hydrogen sulfide hot spots with the detachable, hand-held Jerome? 631-X hydrogen sulfide analyzer.
Gold Film Sensor: Validated in the field and in the lab for over 35 years, our proprietary gold film sensor ensures repeatable results across a wide range of applications.
Weather Station: An attached weather station monitors outside temperature as well as wind speed and direction for increased accuracy in pinpointing the source of odor contamination.
Data Transmission: Advanced data logging and radio telemetry capabilities make downloading data to a remote PC easy and convenient.
PC Software: Intuitive PC software with user selectable time-weighted average reporting and a site view tab give users a bird’s eye view of the monitoring system as a whole.
Programmable Alarms: The 651 comes with programmable alarms that automatically send email alerts if your H2S levels rise above your specified upper limit.
Temperature Controlled Interior: Resistive heating and thermoelectric cooling keep the interior of the 651 at a consistent temperature for increased accuracy.
Regulatory Compliance: The 651 is in active use by many regulatory agencies and landfill, water treatment and wastewater management facilities across the world.
Accessories Parts Consumables
Part Number | Description |
200-0173 | Antenna, 2400 MHz, 8 DB (High Gain) |
200-0181 | Lightning Arrestor, 2400 MHZ |
800-0065 | Vacushield Filter |
980-0010 | Wind Gauge (Anemometer) |
990-0194 | Thermo-Electric Cooler |
2300 0001 | Trimmer Tool |
PS-151 | Tube Nut |
Y990-0194 | Accessory Kit |
Y990-0195 | Flow Pump Kit |
Y990-0279 | Nano Radio Modem Kit |
Y990-0200 | Chlorine Filter Kit |
Y990-0202 | Ammonia Filter Kit |
Y990-0278 | Radio Repeater Kit |
Y2600 3945 | Straight Intake Kit |
Z2600 0918 | Jerome? Functional Test Module, 250 ppb, 115V |
Z2600 0930 | Jerome? Functional Test Module, 30 ppb, 115V |
Z2600 3905 | Zero Air Filter |
Z2600 3930 | Scrubber Filter |
Z2600 3933 | Scrubber Filter, LFS |
Z2600 3934 | Scrubber Filter, LFD |