Multiparameter benchtop pH meter contains 15 options, the meter is suitable for measuring the pH, ORP, ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, DO.
pH Mode:
? 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
? Automatic electrode diagnosis shows the pH slope and offset.
ORP Mode:
? 1 point offset calibration allows adjusting the displayed value to a known standard.
? Relative and absolute millivolt modes ensure the reliable ORP measurements.
Ion Concentration Mode:
? 2 to 5 points calibration, including the 8 concentration points can be selected.
? Direct ion concentration readout simplifies the measurement process.
? Automatic electrode diagnosis shows the calibration points and slopes.
? Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency.
Conductivity/TDS/Salinity/Resistivity Modes:
? 1 to 5 points calibration with automatic recognition for conductivity standards.
? Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear
and pure water compensations, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
? 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
? Salinity and barometric pressure compensations eliminate the measurement error.
Other Features:
? Automatic temperature compensation ensures accurate readings over the entire range.
? Auto-Read function senses and locks the measurement endpoint.
? Calibration due alarm prompts user to calibrate the meter regularly.
? Setup menu allows setting the number of calibration points, stability criteria, temperature
unit, date and time, auto-power off, etc.
? Reset function automatically resumes all settings back to the factory defaults.
? Expanded memory stores or recalls up to 500 data sets.
? USB communication interface for data transfer and timed interval readings.
Specifications
Model | Bante900 |
pH | |
Range | -2.000 to 20.000 pH |
Resolution | 0.001 / 0.01 / 0.1 pH, selectable |
Accuracy | ±0.002 pH |
Calibration Points | 1 to 5 points |
pH Buffer Options | USA / NIST / DIN / 2 custom buffers |
ORP | |
Range | -1999.9 to 1999.9 mV |
Resolution | 0.1 / 1 mV, selectable |
Accuracy | ±0.2 mV |
Calibration Points | 1 point |
Measurement Modes | Relative / Absolute mV |
Ion Concentration | |
Range | 0.00 to 19999 (depending on the range of ISE) |
Resolution | 0.001, 0.01, 0.1, 1, automatic |
Accuracy | ±0.5% F.S. (monovalent), ±1% F.S. (divalent) |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000 |
Measurement Units | ppm, mg/L, mol/L, mmol/L |
Conductivity | |
Range | 0 to 20.00, 200.0, 2000 μS/cm, 20.00, 200.0 mS/cm |
Resolution | 0.001, 0.01, 0.1, 1, automatic |
Accuracy | ±0.5% F.S. |
Calibration Points | 1 to 5 points |
Calibration Solutions | 10 μS / 84 μS / 1413 μS / 12.88 mS / 111.8 mS |
Temperature Coefficient | 0.0 to 10.0%/°C |
Pure Water Compensation | Yes |
Reference Temperature | 20 / 25°C |
Cell Constant | K=0.1 / 1 / 10 / Custom |
TDS | |
Range | 0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt |
Resolution | 0.01, 0.1, 1, automatic |
Accuracy | ±1% F.S. |
TDS Conversion Factor | 0.1 to 1.0 (default 0.5) |
Salinity | |
Range | 0.00 to 80.00 ppt / 0.00 to 42.00 psu |
Resolution | 0.01 |
Accuracy | ±1% F.S. |
Resistivity | |
Range | 0.00 to 20.00 MΩ |
Resolution | 0.01 |
Accuracy | ±1% F.S. |
Dissolved Oxygen | |
Range | 0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation |
Resolution | 0.01 / 0.1, selectable |
Accuracy | ±0.2 mg/L / ±2.0 % |
Calibration Points | 1 or 2 points |
Pressure Correction | 60.0 to 112.5 kPa / 450 to 850 mmHg, manual |
Salinity Correction | 0.0 to 50.0 g/L, manual |
Temperature | |
Range | 0 to 105°C / 32 to 221°F |
Resolution | 0.1°C/°F |
Accuracy | ±0.5°C / ±0.9°F |
Offset Calibration | 1 point |
Calibration Range | Reading ±10°C/°F |
Other Specifications | |
Temperature Compensation | 0 to 100°C / 32 to 212°F, manual or automatic |
Hold Function | Manual / Auto-read measurement endpoint |
Stability Criteria | Low / High |
Calibration Due Alarm | 1 to 31 days or off |
Memory | Stores up to 500 data sets |
Output | USB communication interface |
Connector | BNC, 6-pin mini-DIN, 3.5 mm jack socket |
Display | Custom LCD (125 × 100 mm) |
Power Supply | 5V DC power adapter |
Environmental Conditions | 0 to 50°C / 32 to 122°F, relative humidity < 80% |
Dimensions | 210 × 188 × 60 mm |
Weight | 1.5 kg |