亚洲精品中文字幕乱码三区_性做久久久久久久久一区二区_无码人妻中文字幕一区_亚洲熟妇无码久久精品爱

Welcome to Guangzhou Yihuaxin electronic instrument Co., Ltd!

中文版 ENGLISH

Hotline:08620-36453501

Your location:Home > PRODUCTS > Water Analysis Meters & Electrodes > Bante900 Benchtop pH/Ion/Conductivity/DO Meter

Product Name:Bante900 Benchtop pH/Ion/Conductivity/DO Meter

Bante900 Benchtop pH/Ion/Conductivity/DO Meter
  • Bante900 Benchtop pH/Ion/Conductivity/DO Meter
  • Bante900 Benchtop pH/Ion/Conductivity/DO Meter
  • Bante900 Benchtop pH/Ion/Conductivity/DO Meter
  • Description
  • Details
  • Optional Accessories
  • Multiparameter benchtop pH meter contains 15 options, the meter is suitable for measuring the pH, ORP, ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, DO.


    pH Mode:

    ? 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.

    ? Automatic electrode diagnosis shows the pH slope and offset.


    ORP Mode:

    ? 1 point offset calibration allows adjusting the displayed value to a known standard.

    ? Relative and absolute millivolt modes ensure the reliable ORP measurements.


    Ion Concentration Mode:

    ? 2 to 5 points calibration, including the 8 concentration points can be selected.

    ? Direct ion concentration readout simplifies the measurement process.

    ? Automatic electrode diagnosis shows the calibration points and slopes.

    ? Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency.

    Conductivity/TDS/Salinity/Resistivity Modes:

    ? 1 to 5 points calibration with automatic recognition for conductivity standards.

    ? Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear

      and pure water compensations, seawater and practical salinity measurement modes.


    Dissolved Oxygen Mode:

    ? 1 or 2 points calibration using the air-saturated water or zero oxygen solution.

    ? Salinity and barometric pressure compensations eliminate the measurement error.


    Other Features:

    ? Automatic temperature compensation ensures accurate readings over the entire range.

    ? Auto-Read function senses and locks the measurement endpoint.

    ? Calibration due alarm prompts user to calibrate the meter regularly.

    ? Setup menu allows setting the number of calibration points, stability criteria, temperature

      unit, date and time, auto-power off, etc.

    ? Reset function automatically resumes all settings back to the factory defaults.

    ? Expanded memory stores or recalls up to 500 data sets.

    ? USB communication interface for data transfer and timed interval readings.


    Specifications

    ModelBante900
    pH
    Range-2.000 to 20.000 pH
    Resolution0.001 / 0.01 / 0.1 pH, selectable
    Accuracy±0.002 pH
    Calibration Points1 to 5 points
    pH Buffer OptionsUSA / NIST / DIN / 2 custom buffers
    ORP
    Range-1999.9 to 1999.9 mV
    Resolution0.1 / 1 mV, selectable
    Accuracy±0.2 mV
    Calibration Points1 point
    Measurement ModesRelative / Absolute mV
    Ion Concentration
    Range0.00 to 19999 (depending on the range of ISE)
    Resolution0.001, 0.01, 0.1, 1, automatic
    Accuracy±0.5% F.S. (monovalent), ±1% F.S. (divalent)
    Calibration Points2 to 5 points
    Calibration Solutions0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000
    Measurement Unitsppm, mg/L, mol/L, mmol/L
    Conductivity
    Range0 to 20.00, 200.0, 2000 μS/cm, 20.00, 200.0 mS/cm
    Resolution0.001, 0.01, 0.1, 1, automatic
    Accuracy±0.5% F.S.
    Calibration Points1 to 5 points
    Calibration Solutions10 μS / 84 μS / 1413 μS / 12.88 mS / 111.8 mS
    Temperature Coefficient0.0 to 10.0%/°C
    Pure Water CompensationYes
    Reference Temperature20 / 25°C
    Cell ConstantK=0.1 / 1 / 10 / Custom
    TDS
    Range0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt
    Resolution0.01, 0.1, 1, automatic
    Accuracy±1% F.S.
    TDS Conversion Factor0.1 to 1.0 (default 0.5)
    Salinity
    Range0.00 to 80.00 ppt / 0.00 to 42.00 psu
    Resolution0.01
    Accuracy±1% F.S.
    Resistivity
    Range0.00 to 20.00 MΩ
    Resolution0.01
    Accuracy±1% F.S.
    Dissolved Oxygen
     Range0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation
    Resolution0.01 / 0.1, selectable
    Accuracy±0.2 mg/L / ±2.0 %
    Calibration Points1 or 2 points
    Pressure Correction60.0 to 112.5 kPa / 450 to 850 mmHg, manual
    Salinity Correction0.0 to 50.0 g/L, manual
    Temperature
    Range0 to 105°C / 32 to 221°F
    Resolution0.1°C/°F
    Accuracy±0.5°C / ±0.9°F
    Offset Calibration1 point
    Calibration RangeReading ±10°C/°F
    Other Specifications
    Temperature Compensation0 to 100°C / 32 to 212°F, manual or automatic
    Hold FunctionManual / Auto-read measurement endpoint
    Stability CriteriaLow / High
    Calibration Due Alarm1 to 31 days or off
    MemoryStores up to 500 data sets
    OutputUSB communication interface
    ConnectorBNC, 6-pin mini-DIN, 3.5 mm jack socket
    DisplayCustom LCD (125 × 100 mm)
    Power Supply5V DC power adapter
    Environmental Conditions0 to 50°C / 32 to 122°F, relative humidity < 80%
    Dimensions210 × 188 × 60 mm
    Weight1.5 kg



  • Your Name: