Introduction
Weighing indicator YH-T3 adopts tri-integral A/D conversion technology, widely applied in weighing system equipped with 1~4 load cell.
Standard function
High precision A/D conversion with readability 30000
Able to auto adjust speed and range of digital filter
Able to display in power-saving mode
Protection for low battery
With built in rechargeable 6V/4AH battery
Optional of RS232 interface with selectable baud rate
Auto/manual accumulation
Able to display at 10-time enlargement (counts≤10000)
Able to lock displaying result
Switch between KG/LB
Technical parameter
A/D conversion method | Tri-integral |
A/D conversion speed | ≥40 times/sec. |
Max. A/D conversion | 720000 |
Input signal range | 0mV~10mV |
Input sensitivity | ≥1 μV/e |
Load cell excitation | DC 5V |
Max. connection number of load cell | 4 at 350 ohm |
Verified counts | 3000 |
Max. external counts | 30000 |
Division | 1 | /2/5/10/20/50 optional
Display | 6 bits LED, 6 status indications |
Display range | -99990~99990(d=10) |
Serial communication(optional) | |
Optional standard | RS232C |
Baud Rate | 1200/2400/4800/9600 optional |
Communication method | continuous sending method |
Transmission distance≤30m | |
AC Power | AC 187-242V,49-51Hz |
DC Power | built-in DC 6V/4Ah battery |