Introduction
Weighing indicator XK3190-C8+ adopts fast speed ∑-Δ A/D conversion technology. It is widely applied in electronic batching scale、electronic fix-value scale and electronic catchweigher, sort of control system. Meanwhile, it has function for Max and Min limitation alarm and peak value preserving.
Standard Function
3 inputs, 3 outputs (3 output relays inside) control
High precision A/D conversion with readability 1/30000
With 5 points nonlinearity amend
If change the former indicator, no need to re-calibrate, only to input parameter of former indicator
Embodies with automatic grarimetric filling instruments, catchweigher, alarm for max and min limitation and peak value preserving functions
Able to set fixed-value, pre-act value, Max-min limitation, and delay time freely based on different applications
1-2 materials available for plus/minus scale; external, self-testing, and free max and min modes are available for catchweigher
Standard RS-232/422/485 communication interface, baud rate and way of communication is optional
Standard scoreboard interface serial sending signal by 20mA current loop (constant current)
Precise simulate signal output with mode of 4-20mA/0-20mA/0-5V/0-10V optional, adjustable
Accumulative weight and times is able to be stored, check, delete, and with date-protection when power cut off
Able to connect with serial printer to print weighing record, accumulative amount or combined information, kg, t, g, lb is an optional print unit
Zero tracking, range for zero (automatic and manual) is free to be set
Strong anti-jamming and reliability
ESD protection performance: touch 6KV, air 8KV.
Able to recover from factory setting
Technical Parameter
Accuracy class | III |
AD conversion method | Σ-△ conversion technology |
AD conversion bit | 24bit |
Conversion speed | 80 times/s |
Input signal range | -19mV~+19mV |
Input sensitivity | ≥1uV/e |
Nonlinearity | ≤0.01%F.S |
Full spam temperature | ≤8PPM/ ℃ |
Load cell excitation | DC:5V;350mA |
Numbers of load cell connection | 1~8 load cells 350Ω. |
Method of load cell connection | 6 wire, auto compensation for long distance. |
Display | 7-digit LED, height of bit 0.5 inch, 11 status lights. |
Division | 1/2/5/10/20/50/100 optional |
Clock | able to show real time and date |
Keyboard | 5 soft-touch buttons |
Scoreboard interface | adopts serial sending signal by 20mA current loop |
Communication interface | optional serial communication RS232C/RS422/RS485 and baud rate 600-9600 |
Print interface | share the serial interface, able to connect with serial printer. |
Replay output | capacity of AC: 220V, 0.5A |
External input | on/off touch point (on/off controls in effect), able to connect controller such as proximity switch |
Power supply | AC 110~230V,50/60Hz 1A |
Temperature and humidity in application | 0~40℃;≤90%RH |
Temperature for store and transportation | -20~50℃ |
Weight | about 0.7g |