Stationary airflow transducer hot-wire anemometer. Compact design make it easy to build into other devices. 15 compatible probes available for simultaneous measurement of air velocity, temperature, and humidity. Both analog output and digital output available. 3 systems for analog output enables simultaneous measurement of air velocity, temperature, humidity. Possible to use in various applications such as in buildings, factories, data centers, and more. The best airflow, temperature and humidity sensing device for internet of things (IoT) monitoring.
Features & Benefits
15 types of interchangeable probes for various applications
The smallest airflow probes in the industry
High heat resistance enables precise measurement even in tough environments
Supports digital and analog outputs
Switch to current output or voltage output
Improved probe response and accuracy; micro air velocity limit of 0.01 m/
Applications
Semiconductor manufacturing
Thermal management of automobile electronic control unit (ECU)
Electronic component heat evaluation
Indoor airflow management for semiconductor manufacturing equipment
Data center thermal management
Specifications
Product | Airflow Transducer | |
Model | 6333-00 | |
Air Velocity Measurement Range | 0.01~25.0 m/s(For 0975-00 / 0975-21 / 0975-31) | |
0.01~30.0 m/s(For 0976-03 / 0976-04 / 0976-05 / 0976-07 / 0976-13 / 0976-14 / 0976-15 / 0976-1) | ||
0.01~50.0 m/s(For 0972-00 / 0973-00 / 0975-09 / 0975-10) | ||
Temperature measurement range | 0 ~ 60 ℃(For 0975-31) | |
0 ~100 ℃(For 0976-15 / 0975-21) | ||
0 ~120 ℃(For 0976-05) | ||
Humidity measurement range | 5~ 95 %(For 0975-31) | |
Resolution | Air velocity: 0.01 m/s, Temperature:0.1 ℃, Humidity: 0.1% RH | |
Display units | m/s, ℃, %RH | |
Analog output | Current output and voltage output are switchable with output conversion DIP switch Current output: DC4 ~ 20mA (maximum load: 250Ω) Voltage output: DC 0~5V *Current output is standard setting | |
Interface | RS485 | |
Power supply | Can choose either of the following: AC adapter: Input AC100 ~ 240V, Output DC12V Supply external power to the terminal block: DC12V ~ 24V | |
Power consumption | About 3W (at Power supply voltage: 12V, wind speed 10m / s with probe: 0976-03) | |
Usage environment | Temperature | 0~60℃(No condensation) |
Humidity | 2 % RH ~ 98 % RH | |
Storage environment | Temperature | -10~60℃ (No Condensation) |
Humidity | 2 %RH ~ 95 %RH | |
Size | About 100 (W) × 60 (D) ×25 (H) mm | |
Weight | About 200 g | |
Accessories | Manual: 1, Terminal block: 1 Piece | |
Warranty | 1 Year |
Probe Specifications
Model Number | Measurement Target | Directivity | Air Velocity | Wind Temperature | Humidity | Operating Temperature | Temperature Compensation Sensor | ||||
Measurement Range | Measurement Accuracy | Responsivity | Measurement Range | Measurement Accuracy | Measurement Range | Measurement Accuracy | |||||
0972-00 0973-00 | Wind Speed | Yes | 0.01~50.0m/s | The larger of ± 2% or ± 0.02 m/s of the displayed value | 1 Second | ー | ー | ー | ー | 0-100℃ | ± 5% of displayed value at 0-100 ℃ |
0975-00 | No | 0.01~25.0m/s | 3 Seconds | ||||||||
0975-09 0975-10 | 0.01~50.0m/s | ± 5% of displayed value at 0-120 ℃ | |||||||||
0976-03 0976-04 0976-07 | 0.01~30.0m/s | The larger of ± 3% or ± 0.02 m / s of the displayed value | 0-120℃ | ||||||||
0976-13 0976-14 0976-17 | The larger of ± 2% or ± 0.02 m/s of the displayed value | 0-100℃ | ± 5% of displayed value at 0-100 ℃ | ||||||||
0976-05 | Air Velocity and Temperature | The larger of ± 3% or ± 0.02 m/s of the displayed value | 0~120℃ | ±0.5% | 0-120℃ | ± 5% of displayed value at 0-120 ℃ | |||||
0976-15 | 0~100℃ | 0-100℃ | ± 5% of displayed value at 0-100 ℃ | ||||||||
0975-21 | The larger of ± 2% or ± 0.02 m/s of the displayed value | ||||||||||
0975-31 | Air Velocity, Temperature and Humidity | 0.01~25.0m/s | 0~60℃ | 5~95%RH | 5~80% RH:3% RH 80~90% RH:5% RH |