    The testo 330-1 LL flue gas analysis kit allows you to carry out your service and maintenance inspections quickly and efficiently. The high-quality combustion analyzer combines sophisticated sensor technology and a high level of safety with a long product life span and easy handling


    Two high-quality sensors for O2 and CO

    Bigger savings with Long Life (LL) sensors. (Cells are replaced typically once every six years)

    High-resolution graphic color display

    Integrated sensor monitoring; traffic light color coding system and at-a-glance status

    User-changeable sensors; easy-to-replace sensor filter

    Logger function for up to two hours of continuous measurements

    Large memory for up to 500,000 readings

    Integrated magnets that stick to almost any metal object for easy measuring

    Easy-to-empty condensate collection tank

    4-year warranty without service contract

     

    Delivery Scope

    testo 330-1 LL flue gas analyzer, 12" flue gas probe, with 7’ hose, (10) extra particulate filters, case, AC Power Supply, rechargeable battery, certificate of conformity


  • Differential Pressure

    Measuring range0 to +120 InH?O / 0 to +300 hPa
    Accuracy

    ±0.2 InH?O (0.0 to 20.0 InH?O) / ±0.5 hPa (0.0 to 50.0 hPa)

    ±1 % of mv (20.0 to 40.0 InH?O) / ±1 % of mv (50.1 to 100.0 hPa)

    ±1.5 % of mv (Remaining Range)

    Resolution0.1 InH?O / 0.1 hPa

    Flue gas O?

    Measuring range0 to 21 Vol.%
    Accuracy±0.2 Vol.%
    Resolution0.1 Vol.%
    Reaction time t??< 20 sec


    Flue gas CO

    Measuring range0 to 8000 ppm
    Accuracy

    ±10 ppm or ±10 ppm (0 to 200 ppm)

    ±20 ppm or ±5 ppm (201 to 2000 ppm)

    ±10 % of mv (2001 to 8000 ppm)

    Resolution1 ppm
    Reaction time t??< 60 sec

    Flue gas COlow

    Measuring range0 to 500 ppm
    Accuracy

    ±2 ppm (0 to 39.9 ppm)

    ±5 % of mv (40 to 500 ppm)

    Resolution0.1 ppm
    Reaction time t??< 40 sec

    Flue Gas NO

    Measuring range0 to 3000 ppm
    Accuracy

    ±5 ppm (0 to 100 ppm)

    ±5 % of mv (101 to 2000 ppm)

    ±10 % of mv (2001 to 3000 ppm)

    Resolution1 ppm
    Reaction time t??< 30 sec

    Flue gas NOlow

    Measuring range0 to 300 ppm
    Accuracy

    ±2 ppm (0 to 39.9 ppm)

    ±5 % of mv (40 to 300 ppm)

    Resolution0.1 ppm
    Reaction time t??< 30 sec

    Flue Gas Draft

    Measuring range-4.00 to +16 InH?O / -9.99 to +40 hPa
    Accuracy

    ±0.01 InH?O or ±2 InH?O (-0.50 to +0.24 InH?O) / ±0.02 hPa or ±5 hPa (-0.50 to +0.60 hPa)

    ±0.01 InH?O (+0.24 to +1.20 InH?O) / ±0.03 hPa (+0.61 to +3.00 hPa)

    ±1.5 % of mv (+3.01 to +16.00 InH?O) / ±1.5 % of mv (+3.01 to +40.00 hPa)

    Resolution0.01 InH?O / 0.01 hPa

    Temperature

    Measuring range-40° to 2192 °F / -40 to +1200 °C *
    Accuracy±0.9 °F (32° to 212.0 °F) / ±0.5 °C (0 to +100.0 °C)

    ±0.5 % of mv (Remaining Range)

    Resolution

    0.1 °F (-40° to 1831.8 °F) / 0.1 °C (-40 to +999.9 °C)

    1.0 °F (> +1832 °F) / 1 °C (> +1000 °C)

    * Measuring range depends on the connected flue gas probe


    Efficiency (calculated)

    Measuring range0 to 120 %
    Resolution0.1 %

    Flue Gas loss (calculated)

    Measuring range0 to 99.9 %
    Resolution0.1 %

    Flue Gas CO? calculation (calculated from O?)

    Measuring range0 to CO? max (Display range)
    Accuracy±0.2 Vol.%
    Resolution0.1 Vol.%
    Reaction time t??< 40 sec


    Pressure measurement

    Measuring range0 to +120 InH?O / 0 to +300 hPa
    Accuracy±0.2 InH?O (0.0 to 20.0 InH?O) / ±0.5 hPa (0.0 to 50.0 hPa)

    ±1 % of mv (50.1 to 40.0 InH?O) / ±1 % of mv (50.1 to 100.0 hPa)

    ±1.5 % of mv (Remaining Range)

    Resolution0.1 InH?O / 0.1 hPa

    Flue gas CO (without H?-compensation)

    Measuring range0 to 4000 ppm
    Accuracy±20 ppm (0 to 400 ppm)

    ±5 % of mv (401 to 2000 ppm)

    ±10 % of mv (2001 to 4000 ppm)

    Resolution1 ppm
    Reaction time t??< 60 sec

    Ambient CO

    Measuring range0 to 500 ppm
    Accuracy

    ±5 ppm (0 to 100 ppm)

    ±5 % of mv (> 100 % of mv)

    Resolution1 ppm
    Reaction timeApprox. 35 sec

    with CO probe 0632 3331

    Ambient CO?

    Measuring range

    0 to 1 Vol.%

    0 to 10000 ppm

    Accuracy

    ±75 ppm or ±3 % of mv (0 to 5000 ppm)

    ±150 ppm or ±5 % of mv (5001 to 10000 ppm)

    Reaction timeApprox. 35 sec

    with ambient CO? probe 0632 1240

    Gas leak measurement for combustible gases (via gas leak detection probe)

    Measuring range0 to 10000 ppm CH? / C?H?; Display range
    AccuracySignal optical display (LED) audible signal via buzzer
    Reaction time t??< 2 sec

    General technical data

    Dimensions11 x 4 x 3 in. / 270 x 90 x 65 mm
    Operating temperature23° to 113 °F / -5 to +45 °C
    Protection classIP40
    WarrantyProbe: 48 months; Gas sensors (O?, CO) 48 months; NO sensor 24 months; COlow sensor 24 months; Thermocouple 12 months; rechargeable battery: 12 months
    Display size240 x 320 pixels
    Display functionColour graphic display
    Power supplyRechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A
    Maximum500,000 readings
    Storage temperature-4° to 122 °F / -20 to +50 °C
    Weight21 oz. (without rechargeable battery) / 600 g (without rechargeable battery)